WATER & SANITARY PLUMBING, GAS WORKS
For water and sanitary works, you will have to engage a PUB-licensed plumber. Otherwise, you have to engage an EMA-licensed gas service worker for gas works. The nails, screws, and ramset to be used must have a maximum diameter of 6mm and a penetration depth of 40mm.
Sinks & wash basins
● Repositioning sink or wash basin
○ You must not alter the floor slab.
● Repositioning kitchen sink supported by 63mm-thick hollow walls with tile finish
○ The thickness of the dapoh slab, including the finishes, should not exceed 50mm.
○ You must not alter the floor slab.
Bath & shower
● Installing shower screen
○ You must not alter the floor slab.
● Installing long bath
○ You are not allowed to extend the toilet to accommodate the long bath.
○ You are not allowed to fill the void area below the long bath with cement mortar or other materials.
○ You are not allowed to alter the floor slab.
○ You must allow inspection openings for maintenance in the future.
○ You must provide weep holes.
● Installing shower tray
○ You are not allowed to fill the void area below the long bath with cement mortar or other materials.
○ You are not allowed to alter the floor slab.
○ You must provide weep holes.
● Installing spa pool
○ The pool must be ready-made; hence, the construction of a spa pool using hollow blocks or bricks is not allowed.
○ It must be only installed within the bathroom or toilet as instructed by HDB.
○ The overall weight of the pool, including the water, motor, and other accessories, has a maximum limit of 400kg.
○ Proper water drainage must be available for the spa pool.
○ You are not allowed to alter the floor slab.
Pipes
● Replacing existing PVC water pipe with copper or stainless steel pipe
○ You must comply with the Public Utilities Board’s (PUB) requirements.
○ Only a PUB-licensed plumber can install, fix, alter, replace, or remove any discharge pipe or stack, ventilating pipe or stack, or water pipes.
● Diverting sink waste pipe
○ The pipe must not be fixed in the floor slab, but it can be embedded within floor finishes.
○ You must comply with the Public Utilities Board’s (PUB) requirements.
○ Only a PUB-licensed plumber can install, fix, alter, replace, or remove any discharge pipe/stack or ventilating pipe/stacks.
● Enclosing or encasement of service ducts and piping (excluding gas pipe) using lightweight, non-combustible materials
○ You need to provide at least 600mm-by-600mm removable access opening for inspection and maintenance, as the tiny opening may not give way for the pipe replacement.
○ This enclosure or encasement will have to be removed at the owner’s expense when a total replacement of service ducts or piping is needed.
● Removing the surface-run water pipes
○ You must comply with the Public Utilities Board’s (PUB) requirements.
○ Only a PUB-licensed plumber must carry out such work.
● Removing a surface-run portion of concealed water pipes
○ You must comply with the Public Utilities Board’s (PUB) requirements.
○ Only a PUB-licensed plumber must carry out such work.
○ The pipes should be removed with compression fitting capping (at least 50mm long protruding from the wall).